1.2 PURPOSE OF THE BOOK
To date there are no known text books which offer comprehensive guidance for SIPs structural design. The intention is to collate design friendly methods of structural analysis which draw together strength and stiffness test date, where available, to provide a comprehensive guide to all aspects of design that an engineer will encounter in SIPs design.
To the knowledge of the writer, there are no specific design standards, aside from the USA, in Canada, UK, Europe or any other country. In the USA Eric Tompos, vice president of the National Timber Association, was instrumental is publishing a very useful and concise document: “Engineered Design of Structural Insulated Panels”. This document may be easily found online (pdhonline.com: https://tinyurl.com/2f2vnuxa). It tackles the fundamentals of bending, shear strength, shear walls as diaphragms, bearing, compression and so forth. A more up to date standard: “Structural Insulated Panel Design Specification SIP-EDG01-19S” by SIPA was drafted in 2019. SIPs have been included in the International Residential Code (IRC) which recognises SIPs panels are equivalent to other code approved building systems (ref. SIPA/resources/buildingcodes).
In the UK engineers rely on available data and calculations derived largely from first principles for composite, stressed skin structures. Herein the basis for design checks, except where noted, is Eurocode 5: Recommendations for the Design of Timber Structures (EC5). An accompanying UK document, PD 6693-2, gives supplementary design guidance. British Standard for timber frame design BS5268 part 6.1 is now officially obsolete, although it has been adopted for racking checks in chapter 3. Notwithstanding Eurocode 5, engineers must refer to the British Board of Agrément (BBA) certificates appropriate to the manufactured SIP panel specific to the project in hand for OSB facing properties, racking test values and other parameters.
It is not a text book for the design of timber elements, such as studs in walls which need consideration for compression loading, timber lintels or steel frames. However, where the timber or steel element is an essential component of the structural integrity of the SIP wall, floor or roof assembly, structural properties have been derived from the design code Eurocode 5 and will be quoted where appropriate.
This book is largely based on limit state design to Eurocode 5 employing SI metric units. However, there is no reason why the methods cannot be adapted to permissible design methods by employing unfactored loading, compared with design capacities reduced in proportion with the aggregate ultimate load factors. For engineers who use, for instance, BS5268 part 6.1 (Code of Practice for Timber Frame Walls) the design capacities calculated may be divided by an ultimate load factor. Appropriate advice will be given for all design criteria which follow.
1.3 EXAMPLES OF SIPS CONSTRUCTION
Extracts of examples of SIP construction are shown below which are discussed in this section.
From top: school classroom; workshop making modular units; Nissan hut in the antarctic; site in Cyprus.